Vis enkel innførsel

dc.contributor.authorRøyset, Oddvar
dc.date.accessioned2021-06-29T10:33:23Z
dc.date.available2021-06-29T10:33:23Z
dc.date.issued1996
dc.identifier.isbn82-425-0834-8
dc.identifier.issn0807-7185
dc.identifier.urihttps://hdl.handle.net/11250/2762079
dc.description.abstractThe NO/NO,-monitor and the iodide method are compared with a diffusional sampler for the sampling and determination of nitrogen dioxide in urban air. The results for the diffusional sampler were within 20% of the two other methods for weekly averages. The iodide method and the NO/NO,-monitor showed good agreement; the deviation was within 5%.
dc.language.isoeng
dc.publisherNILU
dc.relation.ispartofNILU TR
dc.relation.ispartofseriesNILU TR; 24/96
dc.subjectPrøvetakere
dc.subjectByluft
dc.subjectNitrogendioksid
dc.titleComparison of diffusive and active sampling methods for the determination of nitrogen dioxide in urban air.
dc.typeResearch report
dc.rights.holder© NILU
dc.source.issue24/96
dc.relation.projectNILU:95042


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel