Show simple item record

dc.contributor.authorEzker, Idoia Beloki
dc.contributor.authorYuan, Bo
dc.contributor.authorBohlin-Nizzetto, Pernilla
dc.contributor.authorBorgen, Anders
dc.contributor.authorWang, Thanh
dc.date.accessioned2024-10-08T12:01:54Z
dc.date.available2024-10-08T12:01:54Z
dc.date.created2024-10-07T13:53:32Z
dc.date.issued2024
dc.identifier.citationChemosphere. 2024, 365, 143326.en_US
dc.identifier.issn0045-6535
dc.identifier.urihttps://hdl.handle.net/11250/3156987
dc.description.abstractPolychlorinated n-alkanes (PCAs) are the main components of chlorinated paraffins (CPs) mixtures, that have been commonly grouped into short-chain (SCCPs, C10–13), medium-chain (MCCPs, C14–17), and long-chain (LCCPs, C18-30) CPs. PCAs pose a significant risk to human health as they are broadly present in indoor environments and are potentially persistent, bioaccumulative, and toxic. The lack of specific terminology and harmonization in analytical methodologies for PCA analysis complicates direct comparisons between studies. The present work summarizes the different methodologies applied for the analysis of PCAs in indoor dust, air, and organic films. The large variability between the reviewed studies points to the difficulties to assess PCA contamination in these matrices and to mitigate risks associated with indoor exposure. Based on our review of physicochemical properties of PCAs and previously reported sum of measurable S/M/LCCPs levels, the homologue groups PCAs–C10–13 are found to be mostly present in the gas phase, PCAs–C14–17 in particulate matter and organic films, and PCAs–C≥18 in settled dust. However, we emphasized that mapping PCA sources and distribution in the indoors is highly dependent on the individual homologues. To further comprehend indoor PCA distribution, we described the uses of PCA in building materials and household products to apportion important indoor sources of emissions and pathways for human exposure. The greatest risk for indoor PCAs were estimated to arise from dermal absorption and ingestion through contact with dust and CP containing products. In addition, there are several factors affecting indoor PCA levels and exposure in different regions, including legislation, presence of specific products, cleaning routines, and ventilation frequency. This review provides comprehensive analysis of available indoor PCA data, the physicochemical properties, applied analytical methods, possible interior sources, variables affecting the levels, human exposure to PCAs, as well as need for more information, thereby providing perspectives for future research studies.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titlePolychlorinated alkanes in indoor environment: A review of levels, sources, exposure, and health implications for chlorinated paraffin mixturesen_US
dc.title.alternativePolychlorinated alkanes in indoor environment: A review of levels, sources, exposure, and health implications for chlorinated paraffin mixturesen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2024 The Authors. Published by Elsevier Ltd.en_US
dc.source.volume365en_US
dc.source.journalChemosphereen_US
dc.identifier.doi10.1016/j.chemosphere.2024.143326
dc.identifier.cristin2310142
dc.source.articlenumber143326en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal