Vis enkel innførsel

dc.contributor.authorVitols, Valentin
dc.date.accessioned2021-06-29T10:32:51Z
dc.date.available2021-06-29T10:32:51Z
dc.date.issued1983
dc.identifier.isbn82-7247-451-4
dc.identifier.urihttps://hdl.handle.net/11250/2762034
dc.description.abstractThe SK sampling system (filter mounted after sampling line and manifold) has been compared to an open-face filter holder mounted outside. The SK system undersamples ambient aerosols due to sampling line losses. Aerosol loss appears to be particle size related, and can exceed 50% for the coarse particles. The two sampling systems gave no significant differences between smoke determinations by the reflectance method.
dc.language.isoeng
dc.publisherNILU
dc.relation.ispartofNILU TR
dc.relation.ispartofseriesNILU TR;14/83
dc.subjectPrøvetaking
dc.subjectPartikler
dc.subjectMåleutstyr
dc.titleAMBIENT PARTICLE LOSSES IN THE SK SAMPLING SYSTEM.
dc.typeResearch report
dc.rights.holder© NILU
dc.source.issue14/83