Vis enkel innførsel

dc.contributor.authorTønnesen, Dag Arild
dc.contributor.authorDye, Christian
dc.contributor.authorBøhler, Trond
dc.date.accessioned2020-12-11T13:15:57Z
dc.date.available2020-12-11T13:15:57Z
dc.date.issued2011
dc.identifier.isbn978-82-425-2467-6
dc.identifier.issn0807-7207
dc.identifier.urihttps://hdl.handle.net/11250/2718734
dc.description.abstractNILU-Norwegian Institute for Air Research has carried out a monitoring campaign around the Mongstad industrial area on behalf of CO2 Technology Centre Mongstad (TCM) to establish the current levels of air and precipitation quality prior to the start-up of the TCM, as well as using the collected data for a recommended permanent surveillance monitoring network in the area. The levels of NOX, particulate matter, formaldehyd and NH3 was at typical rural background level. Ethylamine, methylamine and dimethylamine was found above detection limits. Nitrosamines, nitramines and isocyanates were not found above detection limits. Two of the locations from the baseline study have been recommended
dc.language.isoeng
dc.publisherNILU
dc.relation.ispartofNILU OR
dc.relation.ispartofseriesNILU OR;73/2011
dc.subjectIndustriforurensning
dc.subjectCO2-fangst og lagring (CCS)
dc.subjectLuftkvalitet
dc.titleBaseline study on air and precipitation quality for CO2 Technology Centre Mongstad.
dc.typeResearch report
dc.rights.holder© NILU
dc.source.issue73/2011
dc.relation.projectNILU:111038


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel