Alcoa Mosjøen. Measurements of CF4 and C2F6 emissions from Alcoa Aluminium’s smelter at Mosjøen, Norway.
Research report
Permanent lenke
https://hdl.handle.net/11250/3118085Utgivelsesdato
2024Metadata
Vis full innførselSamlinger
Sammendrag
NILU performed a test campaign for measurements of CF4 and C2F6 for stack emissions at Alcoa Mosjøen Smelter. Time-integrated samples were taken with evacuated canisters combined with low-flow restrictors for continuous sampling periods as long as 4 weeks. The samples were analyzed at NILU with a Medusa preconcentration method combined with GC-MS SIM. As a main conclusion, time integrated sampling together with Medusa GC-MS methodology is a very precise alternative to the traditional attempts to quantify PFC-emission. NILU utførte en testkampanje for målinger av CF4 og C2 F6 fra skorsteinsemisjoner ved Alcoa Mosjøen. Tidsintegrerte prøver ble tatt ved hjelp av evakuerte stålbeholdere kombinert med gass-fløde restriksjoner over en tidsperiode på 14 dager. Prøvene ble analysert på NILU med en Medusa oppkonsentreringsenhet som er koblet til en GC-MS i SIM modus. Metoden viser seg til å være et godt alternativ til de tradisjonelle emisjonsberegninger.